Sample data center site screening report
A useful report should explain why a location deserves the next check—and what would stop it. These three real examples show our desktop screening method. They are not a commissioned buyer shortlist, MegaScout listings or qualified opportunities.
Start with a brief, then judge the evidence
A paid search starts with your markets, required initial and expansion IT load, property size, acquisition or lease preference, and operating date. These examples span different property types to demonstrate the method; they have not been ranked against a common buyer brief.
| Location | Research signal | Immediate decision |
|---|---|---|
| Expand Energy campus · Oklahoma City, OK | Existing data-center infrastructure within a larger marketed campus | Consider scoped document review |
| 6080 Jet Street · Oscoda Township, MI | Former data-center building marketed for technology reuse | Hold capacity or readiness claims |
| 31888 N Alleghany Road · Grayslake, IL | Land explicitly marketed for data-center development | Hold capacity or readiness claims |
Expand Energy campus
Expand Energy campus · Oklahoma City, OK
Published claim
Colliers describes a 103-acre Oklahoma City campus including a 56,250 SF data center and 2.9 MW critical power capacity. Read the Colliers source.
Buyer fit to test
A buyer considering an existing smaller data-center asset. Campus size alone does not establish the size of the available data-center opportunity.
The question that matters next
Does the offered transaction include the data center and its service rights, and can the buyer obtain the required initial load?
Recommended next action
Request the asset schedule, current occupancy, equipment records and utility documents. Reconcile the differing campus totals in the marketing materials.
Current research decision
Advance to scoped document review if the offered asset and market fit the buyer brief. Keep capacity and availability unconfirmed.
Former Air Force data center
6080 Jet Street · Oscoda Township, MI
Published claim
Colliers describes approximately 13,100 SF on 3.6 acres at 6080 Jet Street, Oscoda Township, Michigan, with backup power and cooling. Read the Colliers source.
Buyer fit to test
A buyer open to a smaller reuse or redevelopment candidate, subject to geography, infrastructure condition and project requirements.
The question that matters next
What load can be supported now, what equipment remains serviceable, and which reuse approvals apply?
Recommended next action
Request current service and demand records, equipment condition information, owner-authorized access and applicable use approvals. Scope environmental and engineering reviews.
Current research decision
Hold any capacity-based shortlist decision pending service and condition evidence. A former data-center use is a starting signal.
Grayslake development land
31888 N Alleghany Road · Grayslake, IL
Published claim
JLL markets 243 acres at 31888 N Alleghany Road, Grayslake, Illinois, for data-center development. Read the JLL source.
Buyer fit to test
A land-development search that can accommodate a separate entitlement, service and construction diligence process.
The question that matters next
What portion is usable for the buyer's project, and what parcel-specific service and land-use path can be documented?
Recommended next action
Request parcel boundaries, current disposition, land-use documents, usable-area analysis and a utility assessment tied to the proposed load and schedule.
Current research decision
Hold power and readiness claims pending documents. Consider further land screening only against an actual development brief.
For a deeper local review, see the Northeast screening report, or download the buyer brief (PDF).
What a buyer receives
An agreed research engagement organizes candidate locations, original sources, evidence dates, fit against your brief, unresolved questions and next actions. A search may find that too few candidates meet the brief; we report that result and its reasons instead of filling a shortlist with unsupported sites.
Owner confirmation, utility service, engineering acceptance and transaction diligence are separate milestones. We do not claim those milestones were completed for these examples. Scope and fees are agreed before paid work starts.
One site or a sourcing program?
Tell us how many sites you expect to pursue over the next two years. A single search and a committed multi-site program can need different scope, delivery cadence and commercial terms.
For the comparison framework, read our site-selection checklist and powered-land evidence guide.